![Copley Controls XEL-230-18 Скачать руководство пользователя страница 106](http://html1.mh-extra.com/html/copley-controls/xel-230-18/xel-230-18_user-manual_2666128106.webp)
Xenus Plus User Guide
16-01344 Rev 06
Copley Controls
106
4.9: RS-232 Serial Communications
Mating Connector
6-position, modular connector (RJ-11 style).
Copley Controls provides a prefabricated cable and modular-to-9-pin sub-D adapter in RS-232 Serial
Cable Kit, PN SER-CK.
A diagram of the female connector is shown below.
Pin Description
Pin
Signal
Function
1
N/C
No connection
2
RxD
Receive data input from computer
3
Signal ground
Power supply ground
4
Signal ground
Power supply ground
5
TxD
Transmit data output to computer
6
N/C
No connection
RS-232 Serial Communications Wiring Diagram
XEL, XPL, and XML drives use connector J6. XE2, XP2, XM2, 800-1818 and 800-1819 drives use
connector J7.
1
2
3
4
5
6
Drive
Jx
Rx D
ground
ground
Tx D
To PC
RS-232
Port
Jx-6
Jx-5
Jx-4
Jx-3
Jx-1
Jx-2
Содержание XEL-230-18
Страница 1: ...123123 P N 16 01344 Revision 06 August 30 2019 Xenus Plus User Guide...
Страница 2: ...Xenus Plus User Guide 16 01344 Rev 06 This page for notes...
Страница 9: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 9 This page for notes...
Страница 18: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 18...
Страница 82: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 82 3 25 3 XE2 XP2 XM2 non N models 800 1819 Dimensions...
Страница 116: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 116 Optically Isolated Programmable Outputs Wiring Diagram...
Страница 120: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 120 Analog Input Wiring Diagram Multi Mode Port Interface Diagram...