A.1.6: Determine if Energy Returned Exceeds Drive Capacity
Compare the amount of energy returned to the drive in each deceleration with the drive's energy
absorption capacity. For related drive specifications, see
Regen Circuit Output (p. 67).
For mains voltages not listed in the specification table, use the following formula to determine the
energy that can be absorbed by the drive.
W
capacity
= ½ C (V
regen
2
- (1.414 V
mains
)
2
)
Where:
W
capacity
= The energy that can be absorbed by the bus capacitors, in Joules.
C = Bus capacitance in Farads.
V
regen
= Voltage at which the regen circuit turns on, in volts.
V
mains
= Mains voltage applied to the drive, in volts AC.
A.1.7: Calculate Energy to be Dissipated for Each Deceleration
For each deceleration where the energy exceeds the drive’s capacity, use the following formula to
calculate the energy that must be dissipated by the regen resistor:
E
regen
= E
returned
- E
amp
Where:
E
regen
= Energy that must be dissipated in the regen resistor, in Joules.
E
returned
= Energy delivered back to the drive from the motor, in Joules.
E
amp
= Energy that the drive will absorb, in Joules.
A.1.8: Calculate Pulse Power of Each Deceleration that Exceeds Drive
Capacity
For each deceleration where energy must be dissipated by the regen resistor, use the following
formula to calculate the pulse power that will be dissipated by the regen resistor:
P
pulse
= E
regen
/ T
decel
Where:
P
pulse
= Pulse power in Watts.
E
regen
= Energy that must be dissipated in the regen resistor, in Joules.
T
decel
= Time of the deceleration in seconds.
A.1.9: Calculate Resistance Needed to Dissipate the Pulse Power
Using the maximum pulse power from the previous calculation, calculate the resistance value of the
regen resistor required to dissipate the maximum pulse power: For related drive specifications, see
.
R = V
regen
2
/ P
pulse
max
Where:
R = Resistance in Ohms.
P
pulse max
= The maximum pulse power.
V
regen
= The voltage at which the regen circuit turns on.
Choose a standard value of resistance less than the calculated value. This value must be greater
than the minimum regen resistor value specified in
.
Содержание XEL-230-18
Страница 1: ...123123 P N 16 01344 Revision 06 August 30 2019 Xenus Plus User Guide...
Страница 2: ...Xenus Plus User Guide 16 01344 Rev 06 This page for notes...
Страница 9: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 9 This page for notes...
Страница 18: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 18...
Страница 82: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 82 3 25 3 XE2 XP2 XM2 non N models 800 1819 Dimensions...
Страница 116: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 116 Optically Isolated Programmable Outputs Wiring Diagram...
Страница 120: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 120 Analog Input Wiring Diagram Multi Mode Port Interface Diagram...