Xenus Plus User Guide
16-01344 Rev 06
Copley Controls
71
3.12: Encoder Power Outputs
XEL/XPL/XML
Number
2
Voltage Output
+5 Vdc ±2%
Maximum Current Output
400 mA
Short Circuit Protection
Fold-back current limiting
Function
Provides power for motor encoder and/or Hall switches.
XE2/XP2/XM2/800-1818/800-1819/800-1887
Number
4
Voltage Output
+5 Vdc ±2%
Maximum Current Output
500 mA
Short Circuit Protection
Fold-back current limiting
Function
Provides power for motor encoders and/or Hall switches.
3.13: Primary Encoder Inputs
XEL/XPL/XML
Channels
3
Type
Differential RS-422 line receiver w/ RC filter
Non-isolated
Signals
A, /A, B, /B, S, /S, X*, /X*
Input Voltage Range
±7 Vdc
Differential Input Threshold
±0.2 Vdc
Termination Resistance
121
Maximum Frequency
5 MHz Line (20 Mcount/sec)
Function
Incremental or analog encoder or resolver required for sinusoidal
commutation and position or velocity modes of operation.
* X is equivalent to Marker, Index, or Z channels, depending on the encoder manufacturer. This channel is only
required in certain homing modes while under CAN control.
XE2/XP2/XM2/800-1818
Channels
8
Type
Differential RS-422 line receiver w/ RC filter
Non-isolated
Signals
A, /A, B, /B, S*, /S*, X*, /X* for each axis
Input Voltage Range
±7 Vdc
Differential Input Threshold
±0.2 Vdc
Termination Resistance
A and B Channels: 121
X Channel: 130
with 1 k
pull-up to 5V on X and 1 k
pull-down on /X
S Channel: 221
with 1 k
pull-up to 5V on S and 1 k
pull-down on /S
Maximum Frequency
5 MHz Line (20 Mcount/sec)
Function
Incremental or analog encoder or resolver required for sinusoidal
commutation and position or velocity modes of operation.
* S and X channels are bi-directional.
NOTE: There is no Digital Encoder feedback on 800-1819 and 800-1887 drives.
Содержание XEL-230-18
Страница 1: ...123123 P N 16 01344 Revision 06 August 30 2019 Xenus Plus User Guide...
Страница 2: ...Xenus Plus User Guide 16 01344 Rev 06 This page for notes...
Страница 9: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 9 This page for notes...
Страница 18: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 18...
Страница 82: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 82 3 25 3 XE2 XP2 XM2 non N models 800 1819 Dimensions...
Страница 116: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 116 Optically Isolated Programmable Outputs Wiring Diagram...
Страница 120: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 120 Analog Input Wiring Diagram Multi Mode Port Interface Diagram...