AO1 / AO2 / AO
2
PolyPanel
ls
7
Top wedge block
Top draw blocks
Rigid connector:
2-way 90
˚
2-way 180
˚
3-way
Bottom wedge block
Bottom draw blocks
Panel Installation
Important:
•
Start at a 2-way, 3-way or 4-way connector junction so that the initial panels, once
connected, will remain free-standing; then build from there according to your layout print.
Construct this connector junction at a locatable point from the layout print on the
installation floor. Use chalk line or masking tape to mark the starting location.
•
To connect adjacent panels of equal height, use a rod & block connector.
•
Use a two-way 180
˚
connector for equal or unequal height panels.
•
Two-way 90
˚
, three-way and four-way corner connectors provide the panel-to-panel
connection necessary in either of the following situations:
o
Adjacent panels are unequal in height
o
Adjacent panels are at a 90
˚
angle to each other and of either equal or unequal height.
o
A group of three or four equal- or unequal-height panels at 90
˚
from a common point.
•
At each connector junction where there will be a panel height change, refer to Connector
Change-of-Height procedure.
•
Be sure to level panels before installing components.
Connecting Panels to Connectors:
Equal Height Panels:
Note: Wherever your furniture plan calls for transaction counters mounted to panels, please
review the section “Transaction Counter Installation” before connecting the panels beneath.
1. Place top draw block of connector on the top wedge block of the first panel.
2. Loosen screw in top draw block of connector, with
” Allen wrench or hex bit, until the
bottom draw block of the connector clears the panel’s bottom wedge block.
3. Tighten the same connector draw block
screw until panel and connector are
securely attached.
4. Loosen an/the adjacent top connector
draw block screw.
5. Move the adjacent panel to locate the
bottom wedge block over the bottom draw
block on the connector.
6. Lift up the loosened top draw block on the
connector and position the panels top
wedge block adjacent to the connectors
top wedge block, drop connector draw
block over the two adjacent wedge blocks.
7. Tighten connector draw block screw until
panel and connector are securely
attached.
8. Repeat steps 2 through 7 for any
additional connector draw blocks (3-way
and 4-way connectors).