Reference Guide
E-9
Writer: Your Name Saved by: Lydia Sanchez Saved date: 08/26/99 8:59 AM
Pages: 13 Words: 2459 Template: c:\word7\templates\commapp.dot
File Name e-appe.doc Part Number 158415-001
Power-On Self-Test Messages
Continued
Message
Beeps*
Probable Cause
Recommended Action
1782-Disk Controller
Failure
None
Hard drive circuitry error.
1. Run Computer Setup (F10 Setup).
2. Clear
CMOS.
3. Check cable seating/jumper
settings.
4. Run hard drive diagnostics.
5. Disconnect additional drives.
6. Run the Drive Protection System
test if available.
7. Replace the hard drive.
8. Replace the system board.
1790-Disk 0 Error
None
Hard drive error or wrong
drive type.
1. Run Computer Setup (F10 Setup).
2. Clear
CMOS.
3. Check cable seating jumper
settings.
4. Run hard drive diagnostics.
5. Disconnect additional drives.
6. Confirm drive is supported on this
workstation (large drive ROM
support).
7. Run the Drive Protection System
test if available.
8. Replace the hard drive.
9. Replace the system board.
* L = Long, S = Short
Continued
Содержание Deskpro AP240