2-8
AlphaServer DS20 Service Manual
2.4
Running Diagnostics — Test Command
The test command runs diagnostics on the entire system, CPU devices, memory
devices, and the PCI I/O subsystem. The test command runs only from the SRM
console. Ctrl/C stops the test. The console cannot be secure.
Example 2–2 Test Command Syntax
P00>>> help test
NAME
test
FUNCTION
Test the system.
SYNOPSIS
test [-lb] [-t <time>]
COMMAND ARGUMENT(S):
P00>>>
P00>>>
P00>>>
SYNOPSIS
test ([-lb] [-t <time>]
The entire system is tested by default.
NOTE: If you are running the Microsoft Windows NT operating system, switch from
AlphaBIOS to the SRM console in order to enter the test command. From the
AlphaBIOS console, press in the Halt button (the LED will light) and reset the system,
or select Tru64 UNIX (SRM) or OpenVMS (SRM) from the Advanced CMOS Setup
screen and reset the system.
test [-lb] [-t time]
-lb
Loop back test enable. Loop back connectors are needed on COM1,
COM2, and the parallel port.
-t time
Specifies the run time in seconds. The default for system test is 600
seconds (10 minutes).