Managing the System Remotely
B-13
B.5
Troubleshooting Guide
Table B-3 is a list of possible causes and suggested solutions for symptoms you
might see.
Table B-3 RCM Troubleshooting
Symptom
Possible Cause
Suggested Solution
The local console
terminal is not
accepting input.
Cables not correctly installed.
Switch 1 on switchpack set to
disable.
Check external cable
installation.
Set switch 1 to ON.
The console terminal
is displaying garbage.
System and terminal baud rate
set incorrectly.
Disable RCM and set
the system and terminal
baud rates to 9600
baud.
After the system and
RCM are powered up,
the COM port seems
to hang briefly.
This delay is normal behavior.
Wait a few seconds for
the COM port to start
working.
RCM installation is
complete, but system
does not power up.
RCM Power Control: is set to
DISABLE.
Cables not correctly installed.
Invoke RCM and issue
poweron
command.
Reseat the cables.
You reset the system
to factory defaults, but
the factory settings did
not take effect.
AC power cords were not
removed before you reset
switch 4 on the RCM
switchpack.
Refer to Section B.4.
The message
“unknown command”
is displayed when the
user enters a carriage
return by itself.
The terminal or terminal
emulator is including a
linefeed character with the
carriage return.
Change the terminal or
terminal emulator
setting so that “new
line” is not selected.
Содержание AlphaServer DS20
Страница 8: ......
Страница 50: ......
Страница 90: ......
Страница 122: ...4 32 AlphaServer DS20 Service Manual 4 16 CD ROM Removal and Replacement Figure 4 15 Removing CD ROM PKW0519 97...
Страница 124: ...4 34 AlphaServer DS20 Service Manual 4 17 Floppy Removal and Replacement Figure 4 16 Removing Floppy 1 PK1401 98...
Страница 132: ......
Страница 144: ......
Страница 158: ......