B-10
AlphaServer DS20 Service Manual
B.4
Using the RCM Switchpack
The RCM operating mode is controlled by a switchpack on the server feature
module located in the fan area between the system card cage and the front of the
system. Use the switches to enable or disable certain RCM functions, if desired.
Figure B-2 Location of RCM Switchpack on Server Feature
Module
PK1472-98
1 2 3 4
RCM
Switchpack
Switch
Name
Description
1
EN RCM
Enables or disables the RCM. The default is ON
(RCM enabled). The OFF setting disables RCM.
2
Reserved
Reserved
3
RPD DIS
Enables or disables remote poweroff. The default is
OFF (remote poweroff enabled).
4
SET DEF
Sets the RCM to the factory defaults. The default is
OFF (reset to defaults disabled).