Sequential RF programming mode can be used to register RF sensors. Each device is acquired automatically in sequence with its
own ID. After the control panel has acquired the first sensor, it is ready to acquire the next. If several zone slots are already in use,
a warning message will appear.
• Start from zone:
Used to select the initial zone (first zone to be registered). The zone can be selected by pressing the zone number followed by
Enter, or by selecting it with the arrow keys. After pressing Enter, the system is ready to acquire sensors.
1. After selecting the zone number, the system waits for acquisition of the sensor with the zone number flashing.
2. The installer can now press the registration key on the sensor or remove the battery protector tab, or enter the sensor ID
code.
»
A short chime confirms that registration has take place correctly. If no devices are detected or no code is entered within 60
seconds, the error message “Retry?” will appear. The 60-second timer is deactivated as soon as a number key is pressed
(0 to 9) to enter an ID code.
3. After all sensors have been registered, press (X) to end the procedure and Enter to confirm.
Register zones
This menu can be used to register zones individually and to program its type, properties and various operating parameters.
• Select zone:
This menu entry is used to select the zone number for the device that is being acquired. The number can be entered
directly using the keypad, or it can be selected using the Up/Down arrows. The list shows whether the slot is already in
use (a zone has already been registered to it) or whether it is available. The system will always suggest the first available
position with a logic of filling available spaces.
◊ ID acquisition
If you press “Enter” after selecting the device number, the system waits for acquisition of the device with the zone
number flashing. The installer can now press the registration key on the sensor or remove the battery tab, or enter the
sensor ID code. If no devices are detected or no code is entered within 60 seconds, the error message “Retry?” will
appear. The 60-second timer is deactivated as soon as a number key is pressed (0 to 9) to enter the ID code. If the
device has several inputs, the first index (input “A”) is shown. After the device has been registered, a short chime sounds
and configuration continues.
◊ Zone description
This menu entry is used to enter a description for the acquired zone. The default name for the zones is "zone xx A/B/C",
where A/B/C depends on the zone input index.
◊ Zone type
This menu entry is used to set a zone type for the acquired zone. Refer to the table below for available options. Some
options require addition information to be entered in order to work properly. If additional settings are required for an
option, the “up arrow” will display these sub-options instead of continuing to the next configuration step.