16:25 15/11/2019
***..
Technical menu
Maintenance
Maintenance
Event memory
Event log
Alarm memory
16
Extended menu
When this option is enabled, the installer can see the entire menu. If it is disabled, only the most important menu options are
shown within the technical menu structure. The configurations for parameters on a deeper level are hidden to allow more efficient
navigation of the menus.
Maintenance
Time and date
This menu option is used to import all the parameters relating to the time and date:
• Set time:
the time should be set in HH:MM format
• Date Format:
two types of date format are available: DD:MM:YYYY or MM:DD:YYYY
• Date:
the date should be set according to the relevant format
• Time zone:
choose between UTC-12 and UTC+14
• Daylight saving time:
Europe/USA/Disabled. This function is used to set the control panel to automatically follow daylight
saving time changes according to European or USA standards. The option can also be disabled.
• NTP server:
enable/disable options and addresses are available for up to four NTP servers.
Event log
The control panel can log up to 1024 events. New events are stored in the memory as event # 000. Event 1023 becomes 1024
and is then deleted from the memory.
• Event memory
The event log can be controlled to view the entire list of events.
• Alarm memory
The alarm memory shows alarm events for the most recent arming period. This log is deleted at the next arming.
The possible choices are:
To consult the log:
f
Enter the installer code (default 001961) using the alphanumeric keypad and press the down arrow.
f
Move on to the Service menu using the navigation keypad and enter the menu by pressing Enter/Confirm.
f
Move on to the Event log menu using the navigation keypad and enter the menu by pressing Enter/Confirm.
Cloud syst. name
In this menu you will be asked to enter a name, which will be saved in the cloud, identifying the system. The name will be used to
address the specific installation during remote programming using the Hub Manager software.