Set zones?
< Ok:
↵
>
Zone 01
↓↑
Acquire?
Zone 01
↓↑
1:Edit 2:Del.
Zone 01
Enrolling...
Zone 01
Acquired!
Zone 01
Retry?
Description:
Zone 01
Type:
Alarm
12
Set zones?
The sixth step in the installation wizard is used to register RF sensors.
1. Enter the menu by pressing Enter/Confirm.
2. Select the zone to be registered using the navigation keypad and confirm by pressing Enter/Confirm.
»
If the zone has been assigned to a device, the menu “1:Edit 2:Delete” will be available.
•
Alarm:
This zone type causes an intruder alarm if it is
activated while the system/area is armed.
•
Ent/Exit 1:
The zone can be activated during exit mode
without causing a “Failure” event. Once the system/area
has been armed, zone activation will start the “Entry delay
1” time program for the selected area. This zone type can
only activate an alarm if the exit time has elapsed.
•
Access:
This zone type allows the user to activate the
detector without causing a “Failure” event during the
exit time, or an intruder alarm during the entry time;
nevertheless, the zone will instantly generate an intruder
alarm if activation occurs at any other time.
»
If the zone is free, the control panel waits for a device acquisition signal; refer to the device technical manual for the correct
procedure.
»
If the device has been registered successfully, the control panel displays the message
“Acquired!”
, otherwise the message
“Retry?”
will appear.
3. Enter the device name using the alphanumeric keypad and confirm by pressing Enter/Confirm.
4. Assign a zone type using the navigation keypad and confirm by pressing Enter/Confirm.