
- with sets of bits. The $BIT interval required should be specified giving the first and last bits separated by
“..”. For example, “DISPLAY VAR BIT” “1..15" displays all the $BITs with an index between 1 and 15. A
maximum of 16 bits (on the teach pendant) and 32 bits (for the PCINT) can be displayed at the same time.
Syntax:
DVB
·
Word displays $WORD, in decimal format, hexadecimal or optionally in binary format.
A string of numbers can be used to specify the index of individual items of an array (1-512). The num-
bers are separated by hyphens (-). A set of numbers is separated by two dots (..).
Option:
/Hex displays data in hexadecimal format
/Binary displays the data in binary format.
Syntax:
DVW <string_of_numbers>
EXECUTE COMMAND
Immediate execution of a PDL2 statement
Configure
Display
Execute
Filer
Memory
Program
Set
Utility
The EXECUTE command executes a subset of PDL2 programme instructions from the command level. This
is sometimes referred to as immediate mode execution, as it must be used for the execution of short instruc-
tions with immediate effect (for example setting a predefined variable to a certain value).
An instruction is required as parameter. If the instruction involves references to variables, it is necessary to
specify the programme name as second parameter of the EXECUTE command. The option for the EXE-
CUTE command is available in the second parameter.
Options:
/Context causes association of all references to predefined variables with the
programme
specified. If this option is not used, default values will be used for the predefined
variables and assignments to them will be ineffectual. An error occurs if this option is
used and the programme is not currently active.
Syntax:
E instruction <programme_name>
Example:
E ‘WRITE($ERROR,NL)’ ‘pippo’ — output = 0
E/C ‘WRITE($ERROR, NL)’ ‘pippo’ — output = pippo’s $ERROR
The following instructions cannot be used with the EXECUTE command:
·
WAIT
·
CONDITION
·
ENABLE CONDITION
·
DISABLE CONDITION
·
PURGE CONDITION
Programme variables cannot be created with immediate mode execution.
The control must not be in FATAL status for this command to be valid and system, memory and programme
protection must be disabled. Pressing ^C deactivates execution.
The following conditions concern instructions that cause motion:
·
the key status selector on the control panel must be in the programming position
·
the Auto/Manual selector of the programming terminal must be set to Manual
·
all motion is at a limited safety speed
·
the enable button must be pressed and held during motion
·
START must be pressed and held to maintain motion
·
pressing HOLD suspends motion (which can be restarted with START followed by RUN).
OPERATOR INTERFACE
C3G
Plus
3-32
03/0499
EXECUTE
COMMAND
Содержание C3G Plus
Страница 6: ...This page has been intentionally blank UPDATING LIST C3G Plus D 08 0702 ...
Страница 7: ...C3G Plus PREFACE 05 1199 i PREFACE C3G Plus VERSIONS SDLP SDMP SDHP C3G Plus VERSIONS DDMP DDHP ...
Страница 14: ...This page has been intentionally blank Operations and Maintenance Manual C3G Plus ...
Страница 22: ...This page has been intentionally blank SAFETY REGULATIONS C3G Plus 1 8 02 1299 SAFETY REGULATIONS ...
Страница 24: ...This page has been intentionally blank Operations and Maintenance Manual C3G Plus ...
Страница 26: ...This page has been left intentionally blank INSTALLATION C3G Plus 2 ii 01 0498 SUMMARY ...
Страница 48: ...This page has been intentionally blank Operations and Maintenance Manual C3G Plus ...
Страница 61: ...SAMPLE CONNECTION OF C3G EMC2 C3G Plus OPERATOR INTERFACE 07 1200 3 13 EMERGENCY CONTROL C3G EMC2 ...
Страница 120: ...This page has been left intentionally blank OPERATOR INTERFACE C3G Plus 3 72 05 1199 C3G Plus KIT IVECO ...
Страница 122: ...This page has been intentionally blank Operations and Maintenance Manual C3G Plus ...
Страница 127: ...C3G Plus INTEGRATION GUIDE 06 0400 4 5 SYSTEM I O ...
Страница 143: ...Additional I O modules C3G Plus INTEGRATION GUIDE 01 0498 4 21 parallel i o additional modules ...
Страница 158: ...This page has been intentionally blank INTEGRATION GUIDE C3G Plus 4 36 06 0400 SERIAL I O AND PDL2 TOOLS ...
Страница 160: ...This page has been intentionally blank Operations and Maintenance Manual C3G Plus ...
Страница 182: ...This page has been intentionally blank Operations and Maintenance Manual C3G Plus ...
Страница 188: ...This page has been intentionally blank Operations and Maintenance Manual C3G Plus ...
Страница 190: ...This page has been left intentionally blank MAINTENANCE C3G Plus 7 ii 00 1097 GENERAL RULES ...
Страница 192: ...This page has been left intentionally blank MAINTENANCE C3G Plus 7 2 00 1097 PREVENTIVE MAINTENANCE ...
Страница 195: ...Main C3G Plus Connections C3G Plus MAINTENANCE 08 0702 7 5 FUNCTIONAL LAYOUTS C3G Plus sdlp sdmp sdhp VERSIONS ...
Страница 198: ...Axes Control Circuit MAINTENANCE C3G Plus 7 8 00 1097 FUNCTIONAL LAYOUTS C3G Plus sdlp sdmp sdhp VERSIONS ...
Страница 205: ...Power Supply Distribution Page 1 of 2 C3G Plus MAINTENANCE 01 0498 7 15 FUNCTIONAL LAYOUTS C3G Plus ddmp VERSIONS ...
Страница 206: ...Power Supply Distribution Page 2 of 2 MAINTENANCE C3G Plus 7 16 01 0498 FUNCTIONAL LAYOUTS C3G Plus ddmp VERSIONS ...
Страница 207: ...Machine 1 Axes Control Circuit C3G Plus MAINTENANCE 01 0498 7 17 FUNCTIONAL LAYOUTS C3G Plus ddmp VERSIONS ...
Страница 208: ...Machine 2 Axes Control Circuit MAINTENANCE C3G Plus 7 18 04 0799 FUNCTIONAL LAYOUTS C3G Plus ddmp VERSIONS ...
Страница 209: ...Serial and Parallel Line Connections C3G Plus MAINTENANCE 04 0799 7 19 FUNCTIONAL LAYOUTS C3G Plus ddmp VERSIONS ...
Страница 221: ...SAFETY CIRCUIT TEST DEVICES Connector X113 test device C3G Plus MAINTENANCE 04 0799 7 31 diagnostic C3G Plus ...
Страница 225: ...X30 connector test device C3G Plus MAINTENANCE 01 0498 7 35 diagnostic ...
Страница 232: ...This page has been left intentionally blank MAINTENANCE C3G Plus 7 42 00 1097 CIRCUIT DIAGRAMS ...
Страница 255: ...SOFTWARE OPERATIONS FOR CONTROLLER REPLACEMENT 2 2 C3G Plus MAINTENANCE 01 0498 7 65 SYSTEM SOFTWARE ...
Страница 264: ...This page has been intentionally blank 7 74 08 0702 MAINTENANCE C3G Plus LIST OF SPARE PARTS ...
Страница 265: ...OPERATOR S NOTES C3G Plus NOTES ...
Страница 266: ...C3G Plus NOTES ...