ID-FLX Lite & Telecom Global Guide
180
Group: ATT settings
Setpoint group
ATT settings
Related FW
2.5.0
Range [units]
Default value
-
Step
Comm object
14520
Related applications
Description
Regen Inhibit – set ECU value Aftertreatment Regeneration Inhibit Switch (SPN 3695). There can be
set:
OFF – automatic filter regeneration is enabled - SPN 3695 = 00b
ON – automatic filter regeneration is inhibited - SPN 3695 = 01b
BIN – value is set by LBI Regen Inhibit
Transmitted value is set by actual level of parameter ON/OFF or by level of LBI.
Regen Inhibit
Setpoint group
ATT settings
Related FW
2.5.0
Range [units]
Default value
-
Step
Comm object
14521
Related applications
Description
Regen Force – set ECU value Aftertreatment Regeneration Force Switch (SPN 3696). There can be
set:
OFF – automatic filter regeneration is enabled
ON – automatic filter regeneration is inhibited
BIN – value is set by LBI Regen Force
Transmitted value is activated for 5 sec. by rising edge of parameter change OFF to ON or LBI.
Regen Force
Содержание ID-Lite
Страница 16: ...ID FLX Lite Telecom Global Guide 16 4 3 Terminal diagram and dimension...
Страница 18: ...ID FLX Lite Telecom Global Guide 18 Example Default analog output curves...
Страница 19: ...ID FLX Lite Telecom Global Guide 19 Example Wiring for Dacon gauges and IL NT AOUT8...
Страница 40: ...ID FLX Lite Telecom Global Guide 40 When you finish with adjusting the values click OK and Write to controller...
Страница 41: ...ID FLX Lite Telecom Global Guide 41 5 2 Binary inputs and outputs...
Страница 54: ...ID FLX Lite Telecom Global Guide 54 5 14 Display screens and pages structure...