Notes:
Page 53 of 107
SmartLF Gx Service Manual
When fitting the camera unit, look between the gap in the extrusion
and made sure that the edges of the camera unit scan line is central
to the extrusion gap. If you can see move from one side than the
other, it is incorrect.
If the camera unit scan gap has equal showing through the gap in
the scanner extrusion, this is correct. The unit needs to be equal all
the way along, so the scan line is straight.
11. Tighten the 4 x M3 nuts holding the camera unit up.
Extrusions
Extrusions
Edge of camera unit scan gap