8. Use the following as an indication as to which way to set the FB
figures:
9. Adjust CIS 2 to correct stitch point 1 – 2, then adjust CIS 3 to
adjust the stitch point 2 – 3, and so on until all the CIS arrays
are FB aligned.
10. When you have finished adjusting the FB stitch between all the
CIS arrays, then adjust the LR of these arrays.
FB out, decrease figure
for CIS 2.
FB out, increase figure
for CIS 2.
Good Stitch
CIS CIS CIS CIS CIS
1 2 3 4 5