Notes:
Page 28 of 107
SmartLF Gx Service Manual
6.
Remove board for access panel and store in a static free, safe
environment if the board is being re-fitted. Reposition the
replacement or original board back in the same location.
NOTE: There is metallic tape fitted, which stops stray EMC
emissions from the Gx scanners, make sure this tape is carefully
removed from the old board and refitted to the board being fitting
into the scanner.
7.
Fit one M3 screw in the top central hole to hold the board in
place while fitting the other screws round the board. Start with
the 2 x M4 screws before fitting the other 9 x M3. Leave them
all loose until all the screws are in, then tighten