11. At CIS stitch point 1 & 2, try changing the figure on CIS 2
higher or lower to adjust the LR stitch between the two CIS
arrays. Stitch values can only be positive numbers and the
lowest denomination is ‘0’. It is important that before re-
scanning the media, the ‘Set Stitch’ button MUST be press. The
media should have rewind itself (if the ‘media handling’ is set to
do so), press ‘scan’, if it looks worse try changing the value to
go the other way from the original value and ‘set stitch’ and re-
scan. If it looked like the image was getting better, change the
value again the same way and set and re-scan.
12. Use the following as an indication as to which way to set the LR
figures:
13. Adjust CIS 2 to correct stitch point 1 – 2, then adjust CIS 3 to
adjust the stitch point 2 – 3, and so on until all the CIS arrays
are LR aligned.
LR out, decrease figure
for CIS 2.
LR out, increase
figure for CIS 2.
Good Stitch