Problem
Possible cause
Action
RF15.4 data communication between controller and tool
No serial communication
is possible between the
controller and the base
station. (Error displayed
after
Accept
<F1> is
pressed in
Communica-
tion/Tool
.)
Wrong serial cable is
used.
➔
Use a null modem cable (crossed).
Wrong port is selected
for connection with the
controller.
➔
In the
Communication/Tool
screen of the con-
troller, check the port settings for
RF Serial
.
Note:
If the settings are changed, it is necessary to
press Accept <F1> in order to apply the settings.
➔
Check that the serial cable is connected to the
selected port.
Selected port is used for
serial data transmission.
➔
In the
Communication/Data
Transmission
screen of the controller, check whether serial
data transmission is enabled (the protocol is set
to anything except NONE), and whether the
same port is being used.
➔
If so, select a different port or disable serial data
transmission.
➔
Check all available tools as necessary. The
same port cannot be used for serial data trans-
mission and data communication with base sta-
tion tool.
Power outlet not active.
➔
Check the voltage at the outlet socket where the
base station is plugged in for power supply.
No RF15.4 data commu-
nication is possible
between controller and
tool.
Settings are not config-
ured correctly.
➔
In the
Communication/Tool
screen of the con-
troller, check that
RF settings of the base station
correspond to the settings of the tool, which are
displayed in the
868MHz RF settings
submenu
of the tool. The settings for
Channel, Network ID
and
Tool ID
must match.
Distance between base
station and tool is too
great.
If channel 1 is selected, the distance can be up to
98.4 ft (30 m). If channel 2 or 3 is selected, the dis-
tance can be up to 32.8 ft (10 m).
➔
Increase output power on base station and on
the tool, or move the base station closer to the
tool.
Содержание 17BP B
Страница 4: ...4 P1890E EN 2010 08 90a_ Deckblatt en fm 10 09 2010...
Страница 20: ...20 P1890E EN 2010 08 91b_1_5 en bedingt fm 10 09 2010 First Operation 6...
Страница 48: ...48 P1890E EN 2010 08 91e_Trouble shooting en bedingt fm 10 09 2010 Troubleshooting 9...
Страница 54: ...54 P1890E EN 2010 08 90e_Ersatzteile en fm 10 09 2010 Spare parts 10...