Troubleshooting
9
Problem
Possible cause
Action
868 MHz data communication between controller and tool
No serial communication
is possible between the
controller and the base
station. (Error displayed
after
Accept
<F1> is
pressed in
Communica-
tion/Tool
.)
Wrong serial cable is
used.
➔
Use a null modem cable (crossed).
Wrong port is selected
for connection with the
controller.
➔
In the
Communication/Tool
screen of the con-
troller, check the port settings for
RF Serial
.
Note:
If the settings are changed, it is necessary to
press Accept <F1> in order to apply the settings.
➔
Check that the serial cable is connected to the
selected port.
Selected port is used for
serial data transmission.
➔
In the
Communication/Data
Transmission
screen of the controller, check whether serial
data transmission is enabled (the protocol is set
to anything except NONE), and whether the
same port is being used.
➔
If so, select a different port or disable serial data
transmission.
➔
Check all available tools as necessary. The
same port cannot be used for serial data trans-
mission and data communication with base sta-
tion tool.
Power outlet not active.
➔
Check the voltage at the outlet socket where the
base station is plugged in for power supply.
Содержание 17BP B
Страница 4: ...4 P1890E EN 2010 08 90a_ Deckblatt en fm 10 09 2010...
Страница 20: ...20 P1890E EN 2010 08 91b_1_5 en bedingt fm 10 09 2010 First Operation 6...
Страница 48: ...48 P1890E EN 2010 08 91e_Trouble shooting en bedingt fm 10 09 2010 Troubleshooting 9...
Страница 54: ...54 P1890E EN 2010 08 90e_Ersatzteile en fm 10 09 2010 Spare parts 10...