44
P1890E/EN 2010-08
91e_Trouble shooting en bedingt.fm, 10.09.2010
Troubleshooting
9
No Ethernet communi-
cation is possible
between the controller
and the base station.
(Error displayed after
Accept
<F1>) is pressed
in
Communication/Tool
.)
Wrong Ethernet cable is
used.
➔
A crossover cable is required if the base station
is directly connected to the controller. If the base
station is connected to a switch, a standard
patch cable is required.
IP address of the base
station is not entered
correctly on the control-
ler.
➔
In the
Communication/Tool
screen of the con-
troller, check that the IP address of the base
station is entered in the
RF Base station
field. If
the IP address of the base station is unknown
use the
Network Enabler Administrator
pro-
gram, which is included with each base station.
Note:
If the settings are changed, it is necessary to
press
Accept
<F1> in order to apply the settings.
IP address and subnet
mask are not in the
same range.
Without network administration, it is necessary for
the IP address and subnet mask of the controller to
be in the same range as those of the base station.
➔
Enter the same subnet mask for both IP
addresses and use the same first three num-
bers for the IP addresses on both the controller
and base station.
E.g.:
IP address controller: 192.168.1.xxx
IP address base station: 192.168.1.xxx
Subnet mask: 255.255.255.000
A firewall blocks port
4001.
➔
Reconfigure the firewall so that the specific IP/
MAC address of the tool can use port 4001.
Base station is already
connected to a different
controller.
➔
Check whether any other controller has already
used the same IP address for RF communica-
tion (
RF Base station
).
Power outlet not active.
➔
Check the voltage at the outlet socket where the
base station is plugged in for power supply.
No 868 MHz data com-
munication is possible
between controller and
tool.
Settings are not config-
ured correctly.
➔
In the
Communication/Tool
screen of the con-
troller, check that
RF settings of the base station
correspond to the settings of the tool, which are
displayed in the
868MHz RF settings
submenu
of the tool. The settings for
Channel, Network ID
and
Tool ID
must match.
Distance between base
station and tool is too
great.
If channel 1 is selected, the distance can be up to
98.4 ft (30 m). If channel 2 or 3 is selected, the dis-
tance can be up to 32.8 ft (10 m).
➔
Increase output power on base station and on
the tool, or move the base station closer to the
tool.
Problem
Possible cause
Action
868 MHz data communication between controller and tool
Содержание 17BP B
Страница 4: ...4 P1890E EN 2010 08 90a_ Deckblatt en fm 10 09 2010...
Страница 20: ...20 P1890E EN 2010 08 91b_1_5 en bedingt fm 10 09 2010 First Operation 6...
Страница 48: ...48 P1890E EN 2010 08 91e_Trouble shooting en bedingt fm 10 09 2010 Troubleshooting 9...
Страница 54: ...54 P1890E EN 2010 08 90e_Ersatzteile en fm 10 09 2010 Spare parts 10...