91c_LCD en bedingt.fm, 10.09.2010
P1890E/EN 2010-08
23
LCD display
7
Additional messages in "Linking" mode
Error in last data synchronization with the control.
➔
Synchronize the tool with the control once again.
Tool has not yet been synchronized with a control.
➔
Synchronize the tool with the control for the first time.
The
Tool Enable
input is missing.
➔
Set the
Tool Enable
input.
➔
Synchronize the tool with the control once again.
This message can appear only if
External Tool Enable
has been activated in
Advanced Application Builder\System settings
.
No barcode was detected within the timeout or an invalid barcode was read. The display
switches to
Expect barcod
.
➔
Scan the barcode in again.
First line: The next position to be fastened.
Second line: Number of positions.
Third line: Number of repetitions at this position in case of an NOK rundown.
Linking has been canceled without a batch result.
Not all of the positions in the tightening group have been programmed.
➔
Check the Application and Tightening group selected on the control to determine
whether the tool settings and process programming have been carried out.
Linking result OK.
Linking result NOK.
Linking disabled.
➔
Synchronize the tool with the control once again.
Sync
Error
Tool
not
set
Input
Enable
Missin
Need
Part ID
N.Pos1
of 3
Rpl 0
Linkin
No
Result
Linkin
OK
Linkin
NOK
Linkin
locked
Synch
Содержание 17BP B
Страница 4: ...4 P1890E EN 2010 08 90a_ Deckblatt en fm 10 09 2010...
Страница 20: ...20 P1890E EN 2010 08 91b_1_5 en bedingt fm 10 09 2010 First Operation 6...
Страница 48: ...48 P1890E EN 2010 08 91e_Trouble shooting en bedingt fm 10 09 2010 Troubleshooting 9...
Страница 54: ...54 P1890E EN 2010 08 90e_Ersatzteile en fm 10 09 2010 Spare parts 10...