LCD display
7
7
LCD display
The LCD display on the tool is divided into the result display, status display, operating menu and system
error messages.
7.1
Result display
First line – result:
The status is displayed in alternation with the Application being used.
The LCD display consists of a three lines, each with 6 characters,
to display the status, torque and angle. The result display is updated after the rundown
ends.
OK
Result is OK
NOK
Result is not OK
OFF
Torque encoder offset error
CAL
Torque encoder calibration error
ENC
Angle encoder error
IP
Current overload in output section
IIT
Requested motor output is too high
TMAX
Maximum fastening time exceeded
RC
Rundown terminated by disabled start signal
TS
Depth sensor signal was enabled at start or
was subsequently disabled during the rundown (only for 17BP series)
Tq<
Torque too low
Tq>
Torque too high
A<
Angle Low
A>
Angle High
Error
Error occurred
Second line – Shut-off torque in Nm:
T
Torque Target
Third line – Shut-off angle in degrees:
A
Shut-off angle
The
symbol at the top right shows an interrupted data connection to the control.
OK
T12.00
A100
OK
T12.00
A100
Содержание 17BP B
Страница 4: ...4 P1890E EN 2010 08 90a_ Deckblatt en fm 10 09 2010...
Страница 20: ...20 P1890E EN 2010 08 91b_1_5 en bedingt fm 10 09 2010 First Operation 6...
Страница 48: ...48 P1890E EN 2010 08 91e_Trouble shooting en bedingt fm 10 09 2010 Troubleshooting 9...
Страница 54: ...54 P1890E EN 2010 08 90e_Ersatzteile en fm 10 09 2010 Spare parts 10...