SNMP
Trap Settings
371
Cisco Sx350, SG350X, SG350XG, Sx550X & SG550XG Series Managed Switches, Firmware Release 2.2.5.x
21
Read Write—Management access is read-write. Changes can be made to the device
configuration, but not to the community.
SNMP Admin—User has access to all device configuration options, as well as
permissions to modify the community. SNMP Admin is equivalent to Read Write
for all MIBs except for the SNMP MIBs. SNMP Admin is required for access to the
SNMP MIBs.
-
View Name
—Select an SNMP view (a collection of MIB subtrees to which access
is granted).
•
(Community Type) Advanced
—Select
this type for a selected community.
-
Group Name
—Select an SNMP group that determines the access rights.
STEP 4
Click
Apply
. The SNMP Community is defined, and the Running Configuration is updated.
Trap Settings
The Trap Settings page enables configuring whether SNMP notifications are sent from the
device, and for which cases. The recipients of the SNMP notifications can be configured in the
SNMPv1.2 Notification Recipients
page, or the
SNMPv3 Notification Recipients
page.
To define trap settings:
STEP 1
Click
SNMP
>
Trap Settings
.
STEP 2
Select
Enable
for
SNMP Notifications
to specify that the device can send SNMP
notifications.
STEP 3
Select
Enable
for
Authentication Notifications
to enable SNMP authentication failure
notification.
STEP 4
Click
Apply
. The SNMP Trap settings are written to the Running Configuration file.
Notification Recipients
Trap messages are generated to report system events, as defined in RFC 1215. The system can