Required
Required/As Needed
Onsite
Onsite/Remote
None
Security Level
If the LCD unit is removed from the shelf, wait for at least 5 seconds before plugging it back into the shelf.
In the event the LCD display appears blank, remove the unit from the shelf, wait for at least 5 seconds and
reinsert the unit into the shelf.
Note
Procedure
Step 1
Insert the LCD module in the central slot (between the power slots) of the chassis (see the following figure).
Figure 79: Installing the LCD Module
Step 2
Push the LCD module into the chassis such that the backplane connector is completely engaged (see the above
figure).
Step 3
Tighten the screw to a torque value of 4 in-lb (0.45 N-m) to lock the unit (see the following figure).
Installing the ONS 15454 M6 Shelf
97
Installing the ONS 15454 M6 Shelf
NTP-G255 Install the LCD Module in the ONS 15454 M6 Shelf