Managing the NSS
Configuring SNMP Alerts
Cisco Small Business NSS3000 Series Network Storage System Administration Guide
72
7
You can set up an alert for any of the following:
•
Disk
: When the following occurs: 1) a drive is predicted to fail by S.M.A.R.T.,
2) a drive fails, 3) a drive is above temperature threshold, 4) a volume is
more than 90% full.
•
RAID
: When any of the following occurs: 1) a RAID goes into a degraded
state, 2) a RAID is in a degraded state and will be deactivated (the alert
advises the time at which the RAID will be deactivated), 3) a RAID goes into
a failed state, 4) a RAID is deactivated, 5) a RAID is rebuilt, 6) a RAID is
created.
•
Quota
: When a user or group is over their quota.
•
Backup
: When a backup job completes.
•
Power
: When there is a change in the state of the UPS.
•
Monitor
: When there is an event tracked through the hardware monitor (i.e.,
voltages, fans, and temperatures) that falls out of specification.
STEP 6
Click
Add
.
The management station appears in the
Existing SNMP Trapsinks
list.
STEP 7
Repeat steps 4 through 6 for each SNMP server address to which you want to
send alerts.
STEP 8
To send a test alert for each of the selected conditions to all configured trapsinks,
click
Test All
. To delete an existing SNMP Trapsink, click
Delete
.