355
Warning
Message
Type
Message
Cause/Remedy
Description
ID
MCT Timeout # Set
MCT # timed out Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning.
If the problem persists,
determine if uplink is
sending the current SI
information table.
Disable the warning if
not using the table.
Inband Control Table
was never received.
77100
MCT Timeout # Set
MCT # is lost
Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning.
If the problem persists,
determine if uplink is
sending the current SI
information table.
Disable the warning if
not using the table.
No longer receiving
Inband Control Table.
77100
MCT Timeout # Clear
MCT fault
cleared
–
–
77100
ECT Timeout # Set
ECT # timed out Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning.
If the problem persists,
determine if uplink is
sending the current SI
information table.
Disable the warning if
not using the table.
Event Control Table
was never received.
77200
ECT Timeout # Set
ECT # is lost
Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning.
If the problem persists,
determine if uplink is
sending the current SI
information table.
Disable the warning if
not using the table.
No longer receiving
Event Control Table.
77200
ECT Timeout # Clear
ECT fault cleared –
–
77200
Содержание D9854
Страница 21: ...Declaration of Conformity 410 Index 411 ...
Страница 22: ......
Страница 24: ......
Страница 28: ...Chapter 1 Introduction 4 SCTE 104 pass through support on SDI output NIT Retune Recovery ...
Страница 36: ......
Страница 48: ......
Страница 66: ......
Страница 180: ......
Страница 328: ......
Страница 392: ......
Страница 394: ......
Страница 412: ......
Страница 434: ...Appendix C Compliance 410 Declarationof Conformity ...
Страница 439: ......