Chapter 6 Service and Maintenance
350
Warning
Message
Type
Message
Cause/Remedy
Description
ID
Temperature
Warning
Set
Temperature
over Warning
threshold
Cause: Room
temperature too high, or
air flow is blocked.
Remedy: Check
openings on front and
rear panels for blockage.
Lower the room
temperature or improve
air flow to the device.
Temperature is above
normal operating
range.
44000
Temperature
Warning
Clear
Temperature
normal
–
Temperature is within
the normal operating
range.
44000
FPGA
Temperature
Warning
Set
Temperature
over Warning
threshold
Cause: Room
temperature is too high,
or air flow is blocked.
Remedy: Check the
openings on front and
rear panels for blockage.
Lower the room
temperature or improve
air flow to the device.
FPGA temperature is
above normal
operating range.
45000
FPGA
Temperature
Warning
Clear
Temperature
normal
–
FPGA temperature is
within the normal
operating range.
45000
VBI Data
Set
2nd VBI PID
attempt to write
same line
Cause: Uplink
configuration issue.
Remedy: Contact uplink
to verify expected VBI
settings.
Conflicting VBI data
on second VBI PID.
49000
VBI Data
Clear
Line Collision
Cleared
–
–
49000
TDT timeout #
Set
TDT timed out
Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning.
If the problem persists,
determine if uplink is
sending the current SI
information table.
Disable the warning if
not using the table.
Time Date Table was
never received.
50000
Содержание D9854
Страница 21: ...Declaration of Conformity 410 Index 411 ...
Страница 22: ......
Страница 24: ......
Страница 28: ...Chapter 1 Introduction 4 SCTE 104 pass through support on SDI output NIT Retune Recovery ...
Страница 36: ......
Страница 48: ......
Страница 66: ......
Страница 180: ......
Страница 328: ......
Страница 392: ......
Страница 394: ......
Страница 412: ......
Страница 434: ...Appendix C Compliance 410 Declarationof Conformity ...
Страница 439: ......