Chapter 6 Service and Maintenance
334
Alarm
Message
Type
Message
Cause/Remedy
Description
Severity
ID
DL:NVS Flash
Failure
Set
APP5514 Flash
Write Failed
Cause: Possible
hardware or
software issue.
Remedy: Clear
alarms, reset unit,
and notify Cisco
Services if the
problem persists.
Failed to read
or write flash
memory
Major
27600
DL:NVS Flash
Failure
Set
APP/SAT7109/PP
C CRC/Write has
Failed
Cause: Possible
hardware or
software issue.
Remedy: Clear
alarms, reset unit,
and notify Cisco
Services if the
problem persists.
Failed to read
or write flash
memory
Major
27600
DL:NVS Flash
Failure
Set
TEB Flash Write
Failed
Cause: Possible
hardware or
software issue.
Remedy: Clear
alarms, reset unit,
and notify Cisco
Services if the
problem persists.
Failed to read
or write flash
memory
Major
27600
Temperature
Alarm
Set
Temperature over
Alarm threshold
Cause: Room
temperature too
high, or air flow is
blocked.
Remedy: Check
openings on front
and rear panels for
blockage. Lower
room temperature
or improve air
flow to device.
Temperature is
above safe
operating
range.
Major
28000
Temperature
Alarm
Clear
Temperature
normal
–
Temperature is
within the safe
operating
range.
Major
28000
Содержание D9854
Страница 21: ...Declaration of Conformity 410 Index 411 ...
Страница 22: ......
Страница 24: ......
Страница 28: ...Chapter 1 Introduction 4 SCTE 104 pass through support on SDI output NIT Retune Recovery ...
Страница 36: ......
Страница 48: ......
Страница 66: ......
Страница 180: ......
Страница 328: ......
Страница 392: ......
Страница 394: ......
Страница 412: ......
Страница 434: ...Appendix C Compliance 410 Declarationof Conformity ...
Страница 439: ......