Chapter 5 Web GUI Setup and Monitoring
168
Reacquiring the Network Information
Click
Reacquire
to re-acquire the signal using the tuning parameters from user
settings. The Reacquire Network Information window is displayed.
Check the
Reacquire Tuning & Channel List Only
check box for the decoder to
tune back to the user configured input and frequency and re-acquire the PSI/SI
information back to the selected channel. Click
OK
.
Note:
This operation can take several minutes, depending on the size of the network.
Viewing the Current Input Status
The
RF Tuning Status
area displays the current RF status. The following is an
example:
The following table describes the Current Input Status information displayed:
Parameter
Description
Frequency (GHz)
The current downlink frequency, in GHz.
L band Freq. (MHz)
The current L-Band frequency, in MHz.
Symbol Rate (Msym)
Symbol rate of the received signal, in Msymbols/second.
FEC Rate
The FEC (Forward Error Correction) rate of the received signal
(N/A, 1/2, 3/5, 2/3, 3/4, 4/5, 5/6, 7/8, 8/9 or 9/10).