72-14
Catalyst 4500 Series Switch, Cisco IOS Software Configuration Guide - Cisco IOS XE 3.9.xE and IOS 15.2(5)Ex
Chapter 72 Configuring SNMP
Configuring SNMP
The
snmp-server host
command specifies which hosts receive the notifications. The
snmp-server enable trap
command globally enables the mechanism for the specified notification (for
traps and informs). To enable a host to receive an inform, you must configure an
snmp-server host informs
command for the host and globally enable informs by using the
snmp-server enable traps
command.
To remove the specified host from receiving traps, use the
no snmp-server host
host
global
configuration command. The
no snmp-server host
command with no keywords disables traps, but not
informs, to the host. To disable informs, use the
no snmp-server host informs
global configuration
command. To disable a specific trap type, use the
no snmp-server enable traps
notification-types
global
configuration command.
Setting the Agent Contact and Location Information
To set the system contact and location of the SNMP agent so that these descriptions can be accessed
using the configuration file, perform this task:
Step 5
Switch(config)#
snmp-server enable
traps
notification-types
Enables the switch to send traps or informs and specify the type of
notifications to be sent. For a list of notification types, see
, or enter this:
snmp-server enable traps ?
To enable multiple types of traps, you must enter a separate
snmp-server
enable traps
command for each trap type.
Step 6
Switch(config)#
snmp-server
trap-source
interface-id
(Optional) Specifies the source interface, which provides the IP address
for the trap message. This command also sets the source IP address for
informs.
Step 7
Switch(config)#
snmp-server
queue-length
length
(Optional) Establishes the message queue length for each trap host. The
range is 1 to 1000; the default is 10.
Step 8
Switch(config)#
snmp-server
trap-timeout
seconds
(Optional) Defines how often to resend trap messages. The range is 1 to
1000; the default is 30 seconds.
Step 9
Switch(config)#
end
Returns to privileged EXEC mode.
Step 10
Switch#
show running-config
Verifies your entries.
Step 11
Switch#
copy running-config
startup-config
(Optional) Saves your entries in the configuration file.
Command
Purpose
Command
Purpose
Step 1
Switch#
configure terminal
Enters global configuration mode.
Step 2
Switch(config)#
snmp-server contact
text
Sets the system contact string.
For example:
snmp-server contact Dial System Operator at beeper 21555
.
Step 3
Switch(config)#
snmp-server location
text
Sets the system location string.
For example:
snmp-server location Building 3/Room 222
Step 4
Switch(config)#
end
Returns to privileged EXEC mode.
Содержание Catalyst 4500 Series
Страница 2: ......
Страница 4: ......
Страница 2086: ...Index IN 46 Software Configuration Guide Release IOS XE 3 9 0E and IOS 15 2 5 E ...