37-7
Catalyst 2975 Switch Software Configuration Guide
OL-19720-02
Chapter 37 Configuring EtherChannels and Link-State Tracking
Understanding EtherChannels
To prevent a dual-active situation, the core switches send PAgP protocol data units (PDUs) through the
RSLs to the remote switches. The PAgP PDUs identify the active switch, and the remote switches
forward the PDUs to core switches so that the core switches are in sync. If the active switch fails or
resets, the standby switch takes over as the active switch. If the VSL goes down, one core switch knows
the status of the other and does not change state.
PAgP Interaction with Other Features
The Dynamic Trunking Protocol (DTP) and the Cisco Discovery Protocol (CDP) send and receive
packets over the physical ports in the EtherChannel. Trunk ports send and receive PAgP protocol data
units (PDUs) on the lowest numbered VLAN.
In Layer 2 EtherChannels, the first port in the channel that comes up provides its MAC address to the
EtherChannel. If this port is removed from the bundle, one of the remaining ports in the bundle provides
its MAC address to the EtherChannel.
PAgP sends and receives PAgP PDUs only from ports that are up and have PAgP enabled for the auto
or desirable mode.
Link Aggregation Control Protocol
The LACP is defined in IEEE 802.3ad and enables Cisco switches to manage Ethernet channels between
switches that conform to the IEEE 802.3ad protocol. LACP facilitates the automatic creation of
EtherChannels by exchanging LACP packets between Ethernet ports.
By using LACP, the switch learns the identity of partners capable of supporting LACP and the
capabilities of each port. It then dynamically groups similarly configured ports into a single logical link
(channel or aggregate port). Similarly configured ports are grouped based on hardware, administrative,
and port parameter constraints. For example, LACP groups the ports with the same speed, duplex mode,
native VLAN, VLAN range, and trunking status and type. After grouping the links into an EtherChannel,
LACP adds the group to the spanning tree as a single switch port.
LACP Modes
shows the user-configurable EtherChannel LACP modes for the
channel-group
interface
configuration command.
Both the
active
and
passive LACP
modes enable ports to negotiate with partner ports to an
EtherChannel based on criteria such as port speed and, for Layer 2 EtherChannels, trunking state and
VLAN numbers.
Table 37-2
EtherChannel LACP Modes
Mode
Description
active
Places a port into an active negotiating state in which the port starts negotiations with other
ports by sending LACP packets.
passive
Places a port into a passive negotiating state in which the port responds to LACP packets
that it receives, but does not start LACP packet negotiation. This setting minimizes the
transmission of LACP packets.
Содержание 2975 - Catalyst LAN Base Switch
Страница 36: ...Contents xxxvi Catalyst 2975 Switch Software Configuration Guide OL 19720 02 ...
Страница 40: ...xxxviii Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Preface ...
Страница 62: ...1 22 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 1 Overview Where to Go Next ...
Страница 398: ...13 30 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 13 Configuring VLANs Configuring VMPS ...
Страница 424: ...15 18 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 15 Configuring VTP Monitoring VTP ...
Страница 628: ...26 8 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 26 Configuring UDLD Displaying UDLD Status ...
Страница 660: ...28 8 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 28 Configuring RMON Displaying RMON Status ...
Страница 888: ...38 32 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 38 Troubleshooting Troubleshooting Tables ...