Catalyst 2975 Switch Software Configuration Guide
OL-19720-02
Chapter 12 Configuring Interface Characteristics
Configuring Ethernet Interfaces
If the power supply is over-subscribed to by up to 20 percent, the switch continues to operate but its
reliability is reduced. If the power supply is subscribed to by more than 20 percent, the short-circuit
protection circuitry triggers and shuts the switch down.
For more information about the IEEE power classifications, see the
“Power over Ethernet Ports” section
Beginning in privileged EXEC mode, follow these steps to configure the amount of power budgeted to a
powered device connected to each PoE port on a switch:
To return to the default setting, use the
no power inline consumption default
global configuration
command.
Beginning in privileged EXEC mode, follow these steps to configure amount of power budgeted to a
powered device connected to a specific PoE port:
To return to the default setting, use the
no power inline consumption
interface configuration command.
Command
Purpose
Step 1
configure terminal
Enter global configuration mode.
Step 2
no cdp run
(Optional) Disable CDP.
Step 3
power inline consumption default
wattage
Configure the power consumption of powered devices connected to each
the PoE port on the switch.
The range for each de vice is 4000 to 15400 milliwatts. The default is
15400 milliwatts.
Note
When you use this command, we recommend you also enable
power policing.
Step 4
end
Return to privileged EXEC mode.
Step 5
show power inline consumption
Display the power consumption status.
Step 6
copy running-config startup-config
(Optional) Save your entries in the configuration file.
Command
Purpose
Step 1
configure terminal
Enter global configuration mode.
Step 2
no cdp run
(Optional) Disable CDP.
Step 3
interface
interface-id
Specify the physical port to be configured, and enter interface
configuration mode.
Step 4
power inline consumption
wattage
Configure the power consumption of a powered device connected to a
PoE port on the switch.
The range for each de vice is 4000 to 15400 milliwatts. The default is
15400 milliwatts.
Note
When you use this command, we recommend you also enable
power policing.
Step 5
end
Return to privileged EXEC mode.
Step 6
show power inline consumption
Display the power consumption status.
Step 7
copy running-config startup-config
(Optional) Save your entries in the configuration file.
Содержание 2975 - Catalyst LAN Base Switch
Страница 36: ...Contents xxxvi Catalyst 2975 Switch Software Configuration Guide OL 19720 02 ...
Страница 40: ...xxxviii Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Preface ...
Страница 62: ...1 22 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 1 Overview Where to Go Next ...
Страница 398: ...13 30 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 13 Configuring VLANs Configuring VMPS ...
Страница 424: ...15 18 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 15 Configuring VTP Monitoring VTP ...
Страница 628: ...26 8 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 26 Configuring UDLD Displaying UDLD Status ...
Страница 660: ...28 8 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 28 Configuring RMON Displaying RMON Status ...
Страница 888: ...38 32 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 38 Troubleshooting Troubleshooting Tables ...