17-16
Catalyst 2975 Switch Software Configuration Guide
OL-19720-02
Chapter 17 Configuring MSTP
Configuring MSTP Features
Default MSTP Configuration
shows the default MSTP configuration.
For information about the supported number of spanning-tree instances, see the
Spanning-Tree Instances” section on page 16-10
MSTP Configuration Guidelines
These are the configuration guidelines for MSTP:
•
When you enable MST by using the
spanning-tree mode mst
global configuration command, RSTP
is automatically enabled.
•
For two or more stacked switches to be in the same MST region, they must have the same
VLAN-to-instance map, the same configuration revision number, and the same name.
•
The switch stack supports up to 65 MST instances. The number of VLANs that can be mapped to a
particular MST instance is unlimited.
•
PVST+, rapid PVST+, and MSTP are supported, but only one version can be active at any time. (For
example, all VLANs run PVST+, all VLANs run rapid PVST+, or all VLANs run MSTP.) For more
information, see the
“Spanning-Tree Interoperability and Backward Compatibility” section on
. For information on the recommended trunk port configuration, see the
Other Features” section on page 13-15
•
All stack members run the same version of spanning tree (all PVST+, rapid PVST+, or MSTP). For
more information, see the
“Spanning-Tree Interoperability and Backward Compatibility” section on
.
•
VTP propagation of the MST configuration is not supported. However, you can manually configure
the MST configuration (region name, revision number, and VLAN-to-instance mapping) on each
switch within the MST region by using the command-line interface (CLI) or through the SNMP
support.
Table 17-4
Default MSTP Configuration
Feature
Default Setting
Spanning-tree mode
PVST+ (Rapid PVST+ and MSTP are disabled).
Switch priority (configurable on a per-CIST port basis)
32768.
Spanning-tree port priority (configurable on a per-CIST port basis)
128.
Spanning-tree port cost (configurable on a per-CIST port basis)
1000 Mbps: 4.
100 Mbps: 19.
10 Mbps: 100.
Hello time
2 seconds.
Forward-delay time
15 seconds.
Maximum-aging time
20 seconds.
Maximum hop count
20 hops.
Содержание 2975 - Catalyst LAN Base Switch
Страница 36: ...Contents xxxvi Catalyst 2975 Switch Software Configuration Guide OL 19720 02 ...
Страница 40: ...xxxviii Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Preface ...
Страница 62: ...1 22 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 1 Overview Where to Go Next ...
Страница 398: ...13 30 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 13 Configuring VLANs Configuring VMPS ...
Страница 424: ...15 18 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 15 Configuring VTP Monitoring VTP ...
Страница 628: ...26 8 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 26 Configuring UDLD Displaying UDLD Status ...
Страница 660: ...28 8 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 28 Configuring RMON Displaying RMON Status ...
Страница 888: ...38 32 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 38 Troubleshooting Troubleshooting Tables ...