30-13
Catalyst 2975 Switch Software Configuration Guide
OL-19720-02
Chapter 30 Configuring SNMP
Configuring SNMP
Note
Though visible in the command-line help strings, the
insertion
, and
removal
keywords are not
supported.
You can use the
snmp-server host
global configuration command to a specific host to receive the
notification types listed in
.
Beginning in privileged EXEC mode, follow these steps to configure the switch to send traps or informs
to a host:
port-security
Generates SNMP port security traps. You can also set a maximum trap rate per second. The range
is from 0 to 1000; the default is 0, which means that there is no rate limit.
Note
When you configure a trap by using the notification type
port-security
, configure the port
security trap first, and then configure the port security trap rate:
•
snmp-server enable traps port-security
•
snmp-server enable traps port-security trap-rate
rate
rtr
Generates a trap for the SNMP Response Time Reporter (RTR).
snmp
Generates a trap for SNMP-type notifications for authentication, cold start, warm start, link up or
link down.
storm-control
Generates a trap for SNMP storm-control. You can also set a maximum trap rate per minute. The
range is from 0 to 1000; the default is 0 (no limit is imposed; a trap is sent at every occurrence).
stpx
Generates SNMP STP Extended MIB traps.
syslog
Generates SNMP syslog traps.
tty
Generates a trap for TCP connections. This trap is enabled by default.
vlan-membership
Generates a trap for SNMP VLAN membership changes.
vlancreate
Generates SNMP VLAN created traps.
vlandelete
Generates SNMP VLAN deleted traps.
vtp
Generates a trap for VLAN Trunking Protocol (VTP) changes.
Table 30-5
Switch Notification Types (continued)
Notification Type
Keyword
Description
Command
Purpose
Step 1
configure terminal
Enter global configuration mode.
Step 2
snmp-server engineID remote
ip-address engineid-string
Specify the engine ID for the remote host.
Step 3
snmp-server user
username
groupname
{
remote
host
[
udp-port
port
]} {
v1
[
access
access-list
]
|
v2c
[
access
access-list
]
| v3
[
encrypted
]
[
access
access-list
] [
auth
{
md5
|
sha
}
auth-password
]}
Configure an SNMP user to be associated with the remote host created in
Step 2.
Note
You cannot configure a remote user for an address without first
configuring the engine ID for the remote host. Otherwise, you
receive an error message, and the command is not executed.
Содержание 2975 - Catalyst LAN Base Switch
Страница 36: ...Contents xxxvi Catalyst 2975 Switch Software Configuration Guide OL 19720 02 ...
Страница 40: ...xxxviii Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Preface ...
Страница 62: ...1 22 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 1 Overview Where to Go Next ...
Страница 398: ...13 30 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 13 Configuring VLANs Configuring VMPS ...
Страница 424: ...15 18 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 15 Configuring VTP Monitoring VTP ...
Страница 628: ...26 8 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 26 Configuring UDLD Displaying UDLD Status ...
Страница 660: ...28 8 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 28 Configuring RMON Displaying RMON Status ...
Страница 888: ...38 32 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 38 Troubleshooting Troubleshooting Tables ...