Configuring SNMP Notifications
A trap manager is a management station that receives and processes traps. Traps are system alerts that
the switch generates when certain events occur. By default, no trap manager is defined, and no traps are
sent. Switches running this Cisco IOS release can have an unlimited number of trap managers.
Note
Many commands use the word
traps
in the command syntax. Unless there is an option in the command
to select either traps or informs, the keyword
traps
refers to traps, informs, or both. Use the
snmp-server host
global configuration command to specify whether to send SNMP notifications as
traps or informs.
describes the supported switch traps (notification types). You can enable any or all of these
traps and configure a trap manager to receive them. To enable the sending of SNMP inform notifications,
use the
snmp-server enable traps
global configuration command combined with the
snmp-server host
host-addr
informs
global configuration command.
Table 30-5
Switch Notification Types
Notification Type
Keyword
Description
bridge
Generates STP bridge MIB traps.
cluster
Generates a trap when the cluster configuration changes.
config
Generates a trap for SNMP configuration changes.
copy-config
Generates a trap for SNMP copy configuration changes.
entity
Generates a trap for SNMP entity changes.
cpu threshold
Allow CPU-related traps.
envmon
Generates environmental monitor traps. You can enable any or all of these environmental traps: fan,
shutdown, status, supply, temperature.
errdisable
Generates a trap for a port VLAN errdisabled. You can also set a maximum trap rate per minute.
The range is from 0 to 10000; the default is 0, which means there is no rate limit.
flash
Generates SNMP FLASH notifications. You can optionally enable notification for flash insertion or
removal, which would cause a trap to be issued whenever a switch in the stack is removed or inserted
(physical removal, power cycle, or reload).
fru-ctrl
Generates entity field-replaceable unit (FRU) control traps. In the switch stack, this trap refers to
the insertion or removal of a switch in the stack.
ipmulticast
Generates a trap for IP multicast routing changes.
mac-notification
Generates a trap for MAC address notifications.
msdp
Generates a trap for Multicast Source Discovery Protocol (MSDP) changes.
ospf
Generates a trap for Open Shortest Path First (OSPF) changes. You can enable any or all of these
traps: Cisco specific, errors, link-state advertisement, rate limit, retransmit, and state changes.
pim
Generates a trap for Protocol-Independent Multicast (PIM) changes. You can enable any or all of
these traps: invalid PIM messages, neighbor changes, and rendezvous point (RP)-mapping changes.
Содержание 2975 - Catalyst LAN Base Switch
Страница 36: ...Contents xxxvi Catalyst 2975 Switch Software Configuration Guide OL 19720 02 ...
Страница 40: ...xxxviii Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Preface ...
Страница 62: ...1 22 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 1 Overview Where to Go Next ...
Страница 398: ...13 30 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 13 Configuring VLANs Configuring VMPS ...
Страница 424: ...15 18 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 15 Configuring VTP Monitoring VTP ...
Страница 628: ...26 8 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 26 Configuring UDLD Displaying UDLD Status ...
Страница 660: ...28 8 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 28 Configuring RMON Displaying RMON Status ...
Страница 888: ...38 32 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 38 Troubleshooting Troubleshooting Tables ...