10-4
Catalyst 2975 Switch Software Configuration Guide
OL-19720-02
Chapter 10 Configuring IEEE 802.1x Port-Based Authentication
Understanding IEEE 802.1x Port-Based Authentication
•
If the RADIUS authentication server is unavailable (down) and inaccessible authentication bypass
is enabled, the switch grants the client access to the network by putting the port in the
critical-authentication state in the RADIUS-configured or the user-specified access VLAN.
Note
Inaccessible authentication bypass is also referred to as critical authentication or the AAA fail
policy.
shows the authentication process.
Figure 10-2
Authentication Flowchart
The switch re-authenticates a client when one of these situations occurs:
•
Periodic re-authentication is enabled, and the re-authentication timer expires.
You can configure the re-authentication timer to use a switch-specific value or to be based on values
from the RADIUS server.
141679
Yes
No
Client
identity is
invalid
All authentication
servers are down.
All authentication
servers are down.
Client
identity is
valid
The switch gets an
EAPOL message,
and the EAPOL
message
exchange begins.
Yes
No
1
1
1
1 = This occurs if the switch does not detect EAPOL packets from the client.
Client MAC
address
identity
is invalid.
Client MAC
address
identity
is valid.
Is the client IEEE
802.1x capable?
Start IEEE 802.1x port-based
authentication.
Use inaccessible
authentication bypass
(critical authentication)
to assign the critical
port to a VLAN.
IEEE 802.1x authentication
process times out.
Is MAC authentication
bypass enabled?
Use MAC authentication
bypass.
Assign the port to
a guest VLAN.
Start
Done
Assign the port to
a VLAN.
Done
Done
Assign the port to
a VLAN.
Done
Assign the port to
a restricted VLAN.
Done
Содержание 2975 - Catalyst LAN Base Switch
Страница 36: ...Contents xxxvi Catalyst 2975 Switch Software Configuration Guide OL 19720 02 ...
Страница 40: ...xxxviii Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Preface ...
Страница 62: ...1 22 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 1 Overview Where to Go Next ...
Страница 398: ...13 30 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 13 Configuring VLANs Configuring VMPS ...
Страница 424: ...15 18 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 15 Configuring VTP Monitoring VTP ...
Страница 628: ...26 8 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 26 Configuring UDLD Displaying UDLD Status ...
Страница 660: ...28 8 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 28 Configuring RMON Displaying RMON Status ...
Страница 888: ...38 32 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 38 Troubleshooting Troubleshooting Tables ...