10-31
Catalyst 2975 Switch Software Configuration Guide
OL-19720-02
Chapter 10 Configuring IEEE 802.1x Port-Based Authentication
Understanding IEEE 802.1x Port-Based Authentication
Figure 10-6
Authenticator and Supplicant Switch using CISP
Guidelines
•
You can configure NEAT ports with the same configurations as the other authentication ports. When
the supplicant switch authenticates, the port mode is changed from
access
to
trunk
based on the
switch vendor-specific attributes (VSAs). (device-traffic-class=switch).
•
The VSA changes the authenticator switch port mode from access to trunk and enables 802.1x trunk
encapsulation and the access VLAN if any would be converted to a native trunk VLAN. VSA does
not change any of the port configurations on the supplicant
•
To change the host mode
and
the apply a standard port configuration on the authenticator switch
port, you can also use Auto Smartports user-defined macros, instead of the switch VSA. This allows
you to remove unsupported configurations on the authenticator switch port and to change the port
mode from
access
to
trunk
. For information, see the
AutoSmartports Configuration Guide
.
For more information, see the
“Configuring an Authenticator and a Supplicant Switch with NEAT”
.
Using IEEE 802.1x Authentication with ACLs and the RADIUS Filter-Id Attribute
The switch supports both IP standard and IP extended port access control lists (ACLs) applied to ingress
ports.
•
ACLs that you configure
•
ACLs from the Access Control Server (ACS)
An IEEE 802.1x port in single-host mode uses ACLs from the ACS to provide different levels of service
to an IEEE 802.1x-authenticated user. When the RADIUS server authenticates this type of user and port,
it sends ACL attributes based on the user identity to the switch. The switch applies the attributes to the
port for the duration of the user session. If the session is over, authentication fails, or a link fails, the port
becomes unauthorized, and the switch removes the ACL from the port.
1
Workstations (clients)
2
Supplicant switch (outside wiring closet)
3
Authenticator switch
4
Access control server (ACS)
5
Trunk port
20571
8
1
2
3
5
4
Содержание 2975 - Catalyst LAN Base Switch
Страница 36: ...Contents xxxvi Catalyst 2975 Switch Software Configuration Guide OL 19720 02 ...
Страница 40: ...xxxviii Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Preface ...
Страница 62: ...1 22 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 1 Overview Where to Go Next ...
Страница 398: ...13 30 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 13 Configuring VLANs Configuring VMPS ...
Страница 424: ...15 18 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 15 Configuring VTP Monitoring VTP ...
Страница 628: ...26 8 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 26 Configuring UDLD Displaying UDLD Status ...
Страница 660: ...28 8 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 28 Configuring RMON Displaying RMON Status ...
Страница 888: ...38 32 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 38 Troubleshooting Troubleshooting Tables ...