33-58
Catalyst 2975 Switch Software Configuration Guide
OL-19720-02
Chapter 33 Configuring QoS
Configuring Standard QoS
Beginning in privileged EXEC mode, follow these steps to modify the CoS-to-DSCP map. This
procedure is optional.
To return to the default map, use the
no mls qos cos-dscp
global configuration command.
This example shows how to modify and display the CoS-to-DSCP map:
Switch(config)#
mls qos map cos-dscp 10 15 20 25 30 35 40 45
Switch(config)#
end
Switch#
show mls qos maps cos-dscp
Cos-dscp map:
cos: 0 1 2 3 4 5 6 7
--------------------------------
dscp: 10 15 20 25 30 35 40 45
Configuring the IP-Precedence-to-DSCP Map
You use the IP-precedence-to-DSCP map to map IP precedence values in incoming packets to a DSCP
value that QoS uses internally to represent the priority of the traffic.
shows the default IP-precedence-to-DSCP map:
If these values are not appropriate for your network, you need to modify them.
Command
Purpose
Step 1
configure terminal
Enter global configuration mode.
Step 2
mls qos map cos-dscp
dscp1...dscp8
Modify the CoS-to-DSCP map.
For
dscp1...dscp8
, enter eight DSCP values that correspond to CoS values
0 to 7. Separate each DSCP value with a space.
The DSCP range is 0 to 63.
Step 3
end
Return to privileged EXEC mode.
Step 4
show mls qos maps cos-dscp
Verify your entries.
Step 5
copy running-config startup-config
(Optional) Save your entries in the configuration file.
Table 33-13
Default IP-Precedence-to-DSCP Map
IP Precedence Value
DSCP Value
0
0
1
8
2
16
3
24
4
32
5
40
6
48
7
56
Содержание 2975 - Catalyst LAN Base Switch
Страница 36: ...Contents xxxvi Catalyst 2975 Switch Software Configuration Guide OL 19720 02 ...
Страница 40: ...xxxviii Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Preface ...
Страница 62: ...1 22 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 1 Overview Where to Go Next ...
Страница 398: ...13 30 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 13 Configuring VLANs Configuring VMPS ...
Страница 424: ...15 18 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 15 Configuring VTP Monitoring VTP ...
Страница 628: ...26 8 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 26 Configuring UDLD Displaying UDLD Status ...
Страница 660: ...28 8 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 28 Configuring RMON Displaying RMON Status ...
Страница 888: ...38 32 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 38 Troubleshooting Troubleshooting Tables ...