22-7
Catalyst 2975 Switch Software Configuration Guide
OL-19720-02
Chapter 22 Configuring IGMP Snooping and MVR
Configuring IGMP Snooping
Default IGMP Snooping Configuration
shows the default IGMP snooping configuration.
Enabling or Disabling IGMP Snooping
By default, IGMP snooping is globally enabled on the switch. When globally enabled or disabled, it is
also enabled or disabled in all existing VLAN interfaces. IGMP snooping is by default enabled on all
VLANs, but can be enabled and disabled on a per-VLAN basis.
Global IGMP snooping overrides the VLAN IGMP snooping. If global snooping is disabled, you cannot
enable VLAN snooping. If global snooping is enabled, you can enable or disable VLAN snooping.
Beginning in privileged EXEC mode, follow these steps to globally enable IGMP snooping on the
switch:
To globally disable IGMP snooping on all VLAN interfaces, use the
no ip igmp snooping
global
configuration command.
Table 22-3
Default IGMP Snooping Configuration
Feature
Default Setting
IGMP snooping
Enabled globally and per VLAN
Multicast routers
None configured
Multicast router learning (snooping) method
PIM-DVMRP
IGMP snooping Immediate Leave
Disabled
Static groups
None configured
TCN
1
flood query count
1.
TCN = Topology Change Notification
2
TCN query solicitation
Disabled
IGMP snooping querier
Disabled
IGMP report suppression
Enabled
Command
Purpose
Step 1
configure terminal
Enter global configuration mode.
Step 2
ip igmp snooping
Globally enable IGMP snooping in all existing VLAN interfaces.
Step 3
end
Return to privileged EXEC mode.
Step 4
copy running-config startup-config
(Optional) Save your entries in the configuration file.
Содержание 2975 - Catalyst LAN Base Switch
Страница 36: ...Contents xxxvi Catalyst 2975 Switch Software Configuration Guide OL 19720 02 ...
Страница 40: ...xxxviii Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Preface ...
Страница 62: ...1 22 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 1 Overview Where to Go Next ...
Страница 398: ...13 30 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 13 Configuring VLANs Configuring VMPS ...
Страница 424: ...15 18 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 15 Configuring VTP Monitoring VTP ...
Страница 628: ...26 8 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 26 Configuring UDLD Displaying UDLD Status ...
Страница 660: ...28 8 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 28 Configuring RMON Displaying RMON Status ...
Страница 888: ...38 32 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 38 Troubleshooting Troubleshooting Tables ...