![chromasens allPIXA pro Скачать руководство пользователя страница 97](http://html1.mh-extra.com/html/chromasens/allpixa-pro/allpixa-pro_manual_2605692097.webp)
Chromasens CD40127_R02 allPIXA_pro_User Manual.docx
97
4
Define the area where the reference values should be calculated
The dialog box shows the reference image. On the right side, the following parameters are
shown:
At the
Y position
box and the
Height
box, specify the area which should be used to
calculate the reference values.
Use at least 100 lines for calculating the reference values to eliminate noise. The values
used for the reference are calculated by averaging each column in the selected area.
Click
OK
.
5
Saving reference data
In the
No. of data set
list, click the number of the data set in which the refrence data
should be stored:
If the reference data should not be sent to the camera, clear the
Send to camera
check
box.
To save the reference data to a file as backup, select the
Save to disk
check box, and
then click
Select file
to specify folder and file name.
Click
Next
.
If the reference data are sent to the camera, a progress bar is shown, and the camera is
reset afterward to make sure that the initial settings are again active. The last used
setting is activated automatically.
Again click
Next
to close the wizard.