9.14 Register edit
All registers can be written directly on the camera.
There are two different possibilities to directly manipulate the register:
Permanent modification:
Changes are stored in the setting and are available if the camera is restarted or a setting
is reloaded.
You can find this function in CST at
Camera settings > Special functions > Register
edit
. There are four places for saving register edits directly to a setting.
Non permanent modification:
Changes are transferred to the camera, but they are not stored permanently. If the camera
is restarted or a setting is reloaded, the changes get lost. You can find this function in CST
at the command
Register edit
of the
Advanced
menu.
It is possible to damage the function of the camera by use of this function.
Therefore this function is only available if
User level
has been set to
Guru
.
For more information, see section 6.15
“Setting the user level in CST”.
9.15 Camera information
9.15.1 Camera serial number
Note
All allPIXA pro cameras have an individual serial number.
For any support, provide the serial number of the camera.
Name
Name
Camera serial number
Read only
Function
Returns type and serial number of the camera
Channels
All
Unit
Two integers
Dependency
None
Notes
The first value is the camera type (10020 for the allPIXA pro camera). The
second value is the serial number.
Camera
Value camera type
Value serial number
Lower limit
All
10020
0
Upper limit
All
10020
65535