9.17.7 Line trigger / encoder reduction
Name
Name
Line trigger/encoder reduction
Function
Internal pre-counter for the line trigger or encoder signal; outputs an internal
line trigger after the set value of signals from external line trigger source.
Channels
All
Unit
Integer
Dependency
Only available if the
Enable encoder
check box is selected.
Notes
Camera
Value
Lower limit
All
1
Upper limit
All
256
By use of line trigger reduction, the vertical image resolution is reduced by factor:
𝑇𝑟𝑎𝑛𝑠𝑝𝑜𝑟𝑡𝑅𝑒𝑠𝑜𝑙𝑢𝑡𝑖𝑜𝑛, 𝑟𝑒𝑑𝑢𝑐𝑒𝑑[𝑑𝑝𝑖] =
𝑇𝑟𝑎𝑛𝑠𝑝𝑜𝑟𝑡𝑅𝑒𝑠𝑜𝑙𝑢𝑡𝑖𝑜𝑛[𝑑𝑝𝑖]
Line trigger reduction factor
𝑇𝑟𝑎𝑛𝑠𝑝𝑜𝑟𝑡𝑅𝑒𝑠𝑜𝑙𝑢𝑡𝑖𝑜𝑛, 𝑟𝑒𝑑𝑢𝑐𝑒𝑑[µ𝑚] = Line trigger reduction factor ∗ 𝑇𝑟𝑎𝑛𝑠𝑝𝑜𝑟𝑡𝑅𝑒𝑠𝑜𝑙𝑢𝑡𝑖𝑜𝑛[µ𝑚]
For more information about encoder setup, see section 8.6.