5.5 Electrical installation
WARNING
Only the authorized electro-technical trained staff is permitted to
install and to start operation of the device.
Before connecting and switching on the power supply, make sure that all
required plug connections have been established correctly.
This precaution prevents damage to the allPIXA pro camera or to its
connected components.
When the allPIXA pro camera has been secured in its final working position
and all cables are connected and screwed, check the cable configuration.
The weighting of the cables should not include the connectors one. No
other mechanical strain should be exerted on the connectors.
NOTE
Grounding the housing and the outer cable shield:
Due to an environment with electromagnetic contamination it might be
necessary to establish contact between the housing and / or the outer
shield of the Camera Link cable to the installation’s electrical ground.
The mounting threads for the housing are not isolated; therefore, you may
use any other kind of mounting threads for connecting the housing to the
electrical ground.
Connect a power cable from the camera to a 24V DC power supply.
For the pin allocation of the HIROSE see section 5.1.1.
Figure 28: Connecting the allPIXA pro camera to the power supply
Power: 24 VDC +/- 10 %;
1A; typical 16 W
Hirose 6 -pin