![chromasens allPIXA pro Скачать руководство пользователя страница 175](http://html1.mh-extra.com/html/chromasens/allpixa-pro/allpixa-pro_manual_2605692175.webp)
Chromasens CD40127_R02 allPIXA_pro_User Manual.docx
175
9.8.1 Number of scan lines per image (frame mode)
Name
Name
Number of scan lines per image
Function
Image size in transport direction
Channels
All
Unit
Integer
Dependency
Only in frame scan mode
Notes
Camera:
Value:
Lower limit
All
1
Upper limit
All
1 Meg for fixed object length (use start condition only)
64K for mixed object lenghts (use start and stop
condition)
9.8.2 Image start delay
Name
Name
Image start delay
Function
Delay of image start after frame trigger in lines; the frame trigger could be
taken internally or externally
Channels
All
Unit
Integer
Dependency
Only in frame scan mode
Notes
Camera:
Value:
Lower limit
All
0
Upper limit
All
32767
Sample for use of Image start delay: