![chromasens allPIXA pro Скачать руководство пользователя страница 126](http://html1.mh-extra.com/html/chromasens/allpixa-pro/allpixa-pro_manual_2605692126.webp)
Chromasens CD40127_R02 allPIXA_pro_User Manual.docx
126
4
On the toolbar, click
Show settings
, and then click
White control
in the tree view.
Select the
Enable continuous white control
check box.
In the
Position and mode for white reference mark
list, select the tap for white
control.
Make sure that the
Use sync mode
check box is cleared:
Specify target values in the
Target white reference values
area.
If the white target is placed at the borders of the image, the values may be lower than in
the center.
5
Wait for a balanced image
Check for saturation
Refresh the data in CST
Set the initial gaining values
Burn the setting
6
Check the function by lowering the light in the control zone, for example by a
shadow.