7-8
z
Function group 2
LED
display
Parameter
name
Min/Max
range
Description
Factory
defaults
Adj.
during
run
Page
H 0
[Jump code]
0~95
Sets the code number to jump.
1
O
5-5
H 1
[Fault history 1] -
nOn
-
H 2
[Fault history 2] -
nOn
-
H 3
[Fault history 3] -
nOn
-
H 4
[Fault history 4] -
nOn
-
H 5
[Fault history 5] -
Stores information on the types of
faults, the frequency, the current
and the Accel/Decel condition at
the time of fault. The latest fault is
automatically stored in the H 1-
[Fault history 1].
nOn
-
H 6
[Reset fault
history]
0~1
Clears the fault history saved in H
1-5.
0
O
11-4
H 7
[Dwell
frequency]
0.1~400
[Hz]
When run frequency is issued,
motor starts to accelerate after
dwell frequency is applied to the
motor during H8- [Dwell time].
[Dwell frequency] can be set within
the range of F21- [Max frequency]
and F23- [Start frequency].
5.00
X
H 8
[Dwell time]
0~10
[sec]
Sets the time for dwell operation.
0.0
X
10-5
H10
[Skip frequency
select]
0 ~ 1
Sets the frequency range to skip to
prevent undesirable resonance
and vibration on the structure of
the machine.
0
X
H11
1)
[Skip frequency
low limit 1]
10.00
X
H12
[Skip frequency
high limit 1]
15.00
X
H13
[Skip frequency
low limit 2]
20.00
X
H14
[Skip frequency
high limit 2]
25.00
X
H15
[Skip frequency
low limit 3]
30.00
X
H16
[Skip frequency
high limit 3]
0.1
~400
[Hz]
Run frequency cannot be set
within the range of H11 thru H16.
The frequency values of the low
numbered parameters cannot be
set above those of the high
numbered ones. Settable within
the range of F21 and F23.
35.00
X
9-22
H17
[S-Curve
accel/decel
start side]
1~100
[%]
Set the speed reference value to
form a curve at the start during
accel/decel. If it is set higher, linear
zone gets smaller.
40
X
H18
[S-Curve
accel/decel end
side]
1~100
[%]
Set the speed reference value to
form a curve at the end during
accel/decel. If it is set higher, linear
zone gets smaller.
40
X
9-15
Содержание Titan CI-001-GS2
Страница 1: ...D GS S Compact Space Ve VFD Frequency and 5 5 5 5 8...
Страница 13: ...1 4 Notes...
Страница 16: ...2 3 2 2 Dimensions CI 002 GS2 4 CI 001 GS2 4...
Страница 17: ...2 4 CI 003 GS2 4 CI 005 GS2 4 CI 007 GS2 4 CI 010 GS2 4 H W D W1 A A H1 W1 B B...
Страница 19: ......
Страница 25: ...3 6 5 5 7 5 kW 5 5 mm2 M4 3 5 mm2 M4...
Страница 45: ...6 4 Notes...
Страница 68: ...CHAPTER 8 CONTROL BLOCK DIAGRAM m G k G h Vk Vm w t t...
Страница 71: ...8 4 Notes...
Страница 119: ...10 26 Notes...
Страница 141: ...12 10 Ex 2 100 2 _ _ 1 _ _ _ 76 u steady T acc T steady T dec T dec T H m U X Y...
Страница 159: ...13 18 Notes...
Страница 169: ...15 4...
Страница 170: ...15 5 Notes...
Страница 171: ......