11-12
11.6 Output terminal select at keypad-inverter communication error
Group
Display
Parameter Name
Setting
Range
Default Unit
I/O group
I57
[Output terminal select
when communication
error with keypad]
-
0 ~ 3
0
Select relay output or open collector output when keypad-inverter communication fails.
Keypad and inverter CPU communication is made by serial
communication, delivering information. When communication error occurs
for a certain time,
will be displayed and error signal can be
output to MO or relays.
MFI output relay
MFI output terminal
Bit 1
Bit 0
0
-
-
1
-
3
2
3
-
3
3
3
0: Not used
1: Signal output to MO
2: Signal output to 3A, 3B contacts
3: Signal output to MO, 3A, 3B