AC E
LECTRICAL
S
YSTEM
S
ECTION
3
5627 5/04
Shore 2 -
Switch this breaker group “ON” if you are using a shore power
source to provide electricity to the Line 2 circuit breakers.
Generator (lower) -
Switch this breaker group “ON” if you are using the
generator to provide electricity to the Line 2 circuit breakers.
3.3.2.7 Power Available Indicator
This indicator illuminates when your boat is connected to a working
shore power source.
3.3.2.8 Reverse Polarity Indicators
If reverse polarity occurs, immediately switch the Shore 1 and Shore 2
circuit breaker groups “OFF.” Refer to “3.1.4 Shore Power” for more
information.
Reverse polarity can occur only if your boat was built for use in Europe.
The Line 1 and Line 2 circuits are designed to sense the voltage
difference between the neutral and ground terminal blocks. If the
shore power source is incorrectly wired so that the polarity is re-
versed, the red Reverse Polarity light in the shore power source box
illuminates. If reverse polarity occurs while your boat is connected to
shore power, the Reverse Polarity lights on the AC Control Center
illuminate.
3.3.2.9 Generator Running Indicator
This indicator illuminates when the generator is operating.
3.3.2.10 Receptacles Galley
This breaker controls the flow of electricity to the receptacles in the
galley. Switch this breaker “ON” to supply power to these receptacles.
Use the receptacles as you would the outlets in your home.
NOTE:
If this circuit breaker is “ON” but power is not available at any of
the receptacles in this group, the circuit’s GFCI breaker may have tripped.
Refer to
3.4 Ground Fault Circuit Interrupters
for more information.
3.3.2.11 Receptacles Guest Stateroom
This breaker controls the flow of electricity to the receptacles in the
forward stateroom, third stateroom, and starboard head. Switch this
breaker “ON” to supply power to these receptacles. Use the receptacles
as you would the outlets in your home.
Содержание 56 Voyager SE
Страница 1: ...HIN CDR _________________ 56 Voyager Owner s Guide 2006 Version 1...
Страница 2: ......
Страница 4: ......
Страница 18: ......
Страница 68: ...DC ELECTRICAL SYSTEM SECTION 2 5627 5 04 2 5 DC Schematic M7052D 1...
Страница 69: ...SECTION 2 DC ELECTRICAL SYSTEM 5627 5 04 M7052D 2...
Страница 70: ...DC ELECTRICAL SYSTEM SECTION 2 5627 5 04...
Страница 81: ...SECTION 3 AC ELECTRICAL SYSTEM 5627 5 04 M7044C...
Страница 82: ...AC ELECTRICAL SYSTEM SECTION 3 5627 5 04 M7042C...
Страница 98: ...AC ELECTRICAL SYSTEM SECTION 3 5627 5 04 3 8 AC Schematics 3 8 1 220V 60Hz North South America Asia M7050D 1...
Страница 99: ...SECTION 3 AC ELECTRICAL SYSTEM 5627 5 04 M7050D 2...
Страница 100: ...AC ELECTRICAL SYSTEM SECTION 3 5627 5 04 3 8 2 220V 50Hz Europe Australia M7051D 2...
Страница 101: ...SECTION 3 AC ELECTRICAL SYSTEM 5627 5 04 M7051D 2...
Страница 102: ...AC ELECTRICAL SYSTEM SECTION 3 5627 5 04...
Страница 144: ...PROPULSION SECTION 5 5627 11 03...
Страница 149: ...SECTION 6 OPERATING AND MANEUVERING 5627 11 03 TRACKING FORWARD PROPS ONLY TRACKING ASTERN PROPS ONLY...
Страница 158: ...OPERATING AND MANEUVERING SECTION 6 5627 1103...
Страница 176: ...MAINTENANCE SECTION 7 5627 8 04...
Страница 198: ...SECTION 9 WARRANTY AND PARTS 5627 5 04 SALON DECK Salon A C Unit Engine Room Pilothouse A C Unit Wiring M7097B 2...
Страница 209: ...WARRANTY AND PARTS SECTION 9 5627 5 04 9 9 Carver Limited Warranty...