5. After all waste is removed, flush the waste tank by pouring a few
gallons of fresh water through the “WASTE” deck fitting. Reattach
the vacuum hose to the deck fitting and activate the pumpout
vacuum again to remove the fresh water and any remaining waste.
6. Replace the “WASTE” deck plate.
7. Remove the starboard waste tank deck plate labeled “WASTE” using
the removal tool supplied with your boat. This plate is located on the
starboard side deck amidships, just aft of the port waste tank deck
plate. Refer to
9.7.2 Deck Plates
for the exact location of this plate.
8. Repeat steps 3, 4, 5 and 6 for the starboard waste tank.
4.5.2.2 Overboard Discharge
NOTE:
It is against the law to discharge waste overboard in many areas
of the United States. It is your responsibility to make sure that you are in
compliance with all applicable federal, state and local laws when using
your boat’s overboard discharge system. People who discharge waste
overboard in restricted areas are subject to significant penalties.
In certain coastal areas of the world it is legal to discharge the waste
from your boat’s waste tanks into the sea. To accommodate this proce-
dure Carver offers an optional overboard discharge system for your boat.
This system is available only on boats that are exported or used in the
coastal areas of the United States.
With the overboard discharge system, waste is flushed from the toilets to
the waste tanks where it is stored. Where it is legal, you can then empty
the waste tanks directly overboard. If overboard discharge is not legal
where you are, you can either wait until you reach an area where it is
legal or use a dockside pumpout station to empty the waste tanks.
To empty the tanks:
1. Open the overboard discharge seacock located in the engine room
just aft of the starboard fuel tank. Refer to
9.7.4 Engine Room
for
the exact location of the seacock.
2. Turn the waste tank selector Y-valve so that its handle points to the
port waste tank hose. The Y-valve is located in the engine room near
the starboard forward bulkhead. Refer to
9.7.4 Engine Room
for
the exact location of this valve.
3. Turn the “house” battery bank master disconnect switch to the “ON”
position.
Open Closed
Содержание 56 Voyager SE
Страница 1: ...HIN CDR _________________ 56 Voyager Owner s Guide 2006 Version 1...
Страница 2: ......
Страница 4: ......
Страница 18: ......
Страница 68: ...DC ELECTRICAL SYSTEM SECTION 2 5627 5 04 2 5 DC Schematic M7052D 1...
Страница 69: ...SECTION 2 DC ELECTRICAL SYSTEM 5627 5 04 M7052D 2...
Страница 70: ...DC ELECTRICAL SYSTEM SECTION 2 5627 5 04...
Страница 81: ...SECTION 3 AC ELECTRICAL SYSTEM 5627 5 04 M7044C...
Страница 82: ...AC ELECTRICAL SYSTEM SECTION 3 5627 5 04 M7042C...
Страница 98: ...AC ELECTRICAL SYSTEM SECTION 3 5627 5 04 3 8 AC Schematics 3 8 1 220V 60Hz North South America Asia M7050D 1...
Страница 99: ...SECTION 3 AC ELECTRICAL SYSTEM 5627 5 04 M7050D 2...
Страница 100: ...AC ELECTRICAL SYSTEM SECTION 3 5627 5 04 3 8 2 220V 50Hz Europe Australia M7051D 2...
Страница 101: ...SECTION 3 AC ELECTRICAL SYSTEM 5627 5 04 M7051D 2...
Страница 102: ...AC ELECTRICAL SYSTEM SECTION 3 5627 5 04...
Страница 144: ...PROPULSION SECTION 5 5627 11 03...
Страница 149: ...SECTION 6 OPERATING AND MANEUVERING 5627 11 03 TRACKING FORWARD PROPS ONLY TRACKING ASTERN PROPS ONLY...
Страница 158: ...OPERATING AND MANEUVERING SECTION 6 5627 1103...
Страница 176: ...MAINTENANCE SECTION 7 5627 8 04...
Страница 198: ...SECTION 9 WARRANTY AND PARTS 5627 5 04 SALON DECK Salon A C Unit Engine Room Pilothouse A C Unit Wiring M7097B 2...
Страница 209: ...WARRANTY AND PARTS SECTION 9 5627 5 04 9 9 Carver Limited Warranty...