169
LEGEND FOR FIG. 71
AC
— Alternating Current
ACB
— Analog Control Board
AWG
— American Wire Gage
CBx
— Circuit Breaker
CPTx
— Control Power Transformer
CTx
— Current Transformer
DI
— Drive Input Contactor
DI-IV
— Drive Input Contactor Intellivac Module
DIC
— Drive Input Control Relay
DICR1
— Drive Input Contactor Pilot Relay
DIIS
— Drive Input Isolating Switch
DILR
— Drive Input Line Reactor
DIOL
— Drive Input Overload
DIOLx
— Drive Input Overload Auxiliary Relay
DITB
— Drive Input Contactor Terminal Blocks
DSx
— Disconnect Switch
EMC
— Electro-Magnetic Choke
ES
— Ethernet Switch
FLT
— Fault Relay
Fx
— Fuse
GFCT
— Ground Fault Current Transformer
GND
— Ground
GRD
— Ground
HECSU
— Hall Effect Current Sensor (U Phase)
HECSW
— Hall Effect Current Sensor (W Phase)
HPR
— High Pressure Relay
IFM
— Interface Module
ISM
— Integrated Starter Module
LFC
— Line Filter Capacitors
LFRNx
— Line Reactor Fan x
LV
— Low Voltage
LVx
— External Low Voltage Supply
MFC
— Motor Filter Capacitors
MFN1C
— Main Fan Contactor
MFN1MP — Main fan Motor Protector
MOV
— Metal Oxide Varistor
MSR
— Monitoring Safety Relay
MSRXx
— Monitoring Safety Relay Auxiliary Relay x
MV
— Medium Voltage
NR
— Neutral Resistor
PE
— Earth Ground
PFN1
— Powerflex Interface Board
PP
— Carrier Power Panel
PS1A
— AC/DC Converter
PS2
— DC/DC Converter
PS4
— AC/DC Converter
RUN
— Run Relay
SS
— Surge Suppressor
ST
— Shunt Trip
VFD
— Variable Frequency Drive
VSBx
— Voltage Sensing Board
WRN
— Warning Relay
XIOx
— External Inputs/Outputs
1M
— Start Relay
66
Carrier ISM to be programmed by Carrier before
start-up. Relay contacts shown without signal
power applied.
71
Calibrate for 4-20 mA; 0-5 vdc (Default 0-10 vdc).
100
WARNING: Ground must be connected to prevent
high voltages from being applied to drive control
boards.
104
Located in drive low voltage control section.
105
Device is mounted on the low voltage door of the
drive.
WIRING
Factory Wiring
Field Wiring
Mechanically Connected
Conductor, Crossing of Paths or Conductors
Not Connected
Conductor, Junction of Connected Paths, Con-
ductors or Wires
Conductor, Separable or Jacks Engaged
Terminal
Terminal (Rockwell Automation use only)
Terminal Blocks
— Barrier
Wired To/From Destination
SWITCHES AND INPUT DEVICES
Contact Normally Open (Make)
Contact Normally Closed (Break)
OUTPUT DEVICES
Fan (3 Phase Induction Motor)
Induction Machine
RESISTORS, CAPS, WINDINGS AND
GROUND
Capacitor
Winding
Transformer, Current
PROTECTION
Circuit Breaker, Control/Power
Fuse, Control/Power
Surge Suppressor
POWER ELECTRONIC DEVICES
Symmetrical Gate-Commutated Thyristor and
Gate Driver Board
MISCELLANEOUS
Note Number Indicator
Contact Location Description
Relay Location Description
Key Interlock on Isolation Switch
Key Interlock on MV Door
Multiple Barrel Key Interlock on Isolation Switch
Multiple Barrel Key Interlock on MV Door
Transfer Block
Содержание AquaEdge 19XR series
Страница 69: ...69 Fig 33 19XR Leak Test Procedures a19 1625 ...
Страница 150: ...150 Fig 62 PIC II Control Panel Wiring Schematic Frame 2 3 4 and E Compressors without Split Ring Diffuser a19 1870 ...
Страница 152: ...152 a19 1871 Fig 63 PIC II Control Panel Wiring Schematic Frame 4 and 5 Compressors with Split Ring Diffuser ...
Страница 154: ...154 Fig 64 Benshaw Inc Wye Delta Unit Mounted Starter Wiring Schematic Low Voltage a19 1873 ...
Страница 161: ...161 Fig 69 Typical Low Voltage Variable Frequency Drive VFD Wiring Schematic 575 v ...
Страница 162: ...162 Fig 69 Typical Low Voltage Variable Frequency Drive VFD Wiring Schematic 575 v cont ...
Страница 163: ...163 Fig 69 Typical Low Voltage Variable Frequency Drive VFD Wiring Schematic 575 v cont a19 1880 ...
Страница 176: ...176 CONTINUED ON NEXT PAGE Fig 71 Typical Medium Voltage Variable Frequency Drive VFD Wiring Schematic cont a19 2064 ...
Страница 186: ...186 APPENDIX B LEAD LAG WIRING 19XR Lead Lag Schematic Series Cooler Flow a19 1655 ...
Страница 187: ...187 APPENDIX B LEAD LAG WIRING cont 19XR Lead Lag Schematic Parallel Cooler Flow a19 1717 ...